• co-ax valves inc.
    cx-tec valves
    The Smart Choice in Process Control

cx-tec valves

direct acting solenoid valves

CXD 2/2 Way Valves

  • Orifice: DN 10 - 25 mm
  • Function: NC / NO
  • Pressure Range: PN 0 - 40 bar / 0 - 600 psi
  • Nominal Voltage: DC 24 V / AC 110 V
  • Body Materials: Brass, Stainless Steel

cx-tec CXD 2/2 Way Valve

Data Sheet CXD 2/2 Way Valves

General Operating Manual cx-tec Valves

Installation Instructions cx-tec Valves

Price List CXD Valves

CXD DR 3/2 Way Valves

  • Orifice: DN 10 - 25 mm
  • Function: NC / NO
  • Pressure Range: PN 0 - 40 bar / 0 - 600 psi
  • Nominal Voltage: DC 24 V / AC 110 V
  • Body Material: Brass

cx-tec CXD 3/2 Way Valves

Data Sheet CXD DR 3/2 Way Valves

General Operating Manual cx-tec Valves

Installation Instructions cx-tec Valves

Price List CXD Valves

externally controlled air operated valves

CXF 2/2 Way Valves

  • Orifice: DN 10 - 25 mm
  • Function: NC / NO
  • Pressure Range: PN 0 - 40 bar / 0 - 600 psi
  • Body Materials: Brass, Stainless Steel

cx-tec CXF 2/2 Way Valves

Data Sheet CXF 2/2 Way Valves

General Operating Manual cx-tec Valves

Installation Instructions cx-tec Valves

Declaration of Conformity 94/9/EC CXF Valves

Price List CXF Valves

CXF DR 3/2 Way Valves

  • Orifice: DN 10 - 25 mm
  • Function: NC / NO
  • Pressure Range: PN 0 - 40 bar / 0 - 600 psi
  • Body Material: Brass

cx-tec CXF 3/2 Way Valves

Data Sheet CXF DR 3/2 Way Valves

General Operating Manual cx-tec Valves

Installation Instructions cx-tec Valves

Declaration of Conformity 94/9/EC CXF Valves

Price List CXF Valves

accessories

Mounting Brackets

  • DN 10 - 25
  • Material: Stainless Steel

cx-tec Mounting Brackets

Installation Instructions Mounting Brackets

Limit Switch Reed

  • AC / DC 10 - 30 V
  • for CXF and CXF DR

cx-tec Limit Switch Reed

Installation Instructions Limit Switch Reed

5/2 Way Pilot Valve

  • DC 24 V / AC 110 V
  • for CXF and CXF DR

cx-tec 5/2 Way Pilot Valve

Installation Instructions 5/2 Way Pilot Valve

Coaxial Valve Technology

Valve Principle CXD Valves

cx-tec CXD Valve Animation

(d) coil

Coaxial valves have a single moving part: the control tube (a).

When the control tube is actuated by an electromagnet (Figure A) or a pneumatic / hydraulic signal to the actuator (Figure B) the tube moves away from the valve seat (b).

This allows the media to flow straight through without deviation. Powering the tube back against the seat closes the valve. The tube is held against the seat independent of system pressure. This provides positive shut-off and compensates for seat wear. Dynamic seals (c) prevent shaft leakage.

Valve Principle CXF Valves

cx-tec CXF Valve Animation

(e) actuator ports

COMPANY

müller co-ax was founded in 1960 by Gottfried Müller, the inventor of the first coaxial valve. The Headquarter is located in Southern Germany. For over 55 years, müller co-ax ag has set the standard for the development and integration of co-ax® valve technology into virtually an unlimited number of flow control applications.

co-ax valves inc, is the U.S. subsidiary of müller co-ax ag and provides valve solutions to meet the highest, ever changing fluid and gas flow control requirements.

co-ax brand

co-ax brand valves are configured to meet exact application requirements.

co-ax valves are not just another "valve-in-a-box". Using a wide selection of orifice sizes, port connections, seal and seat configurations, our experienced application engineers tailor valves for maximum performance in your application. Whether you need one valve or one hundred. Simple shut-off valves to flow or pressure control, single valves or multiple valve manifolds, we can save you space, time and money!

cx-tec brand

cx-tec brand valves are standardized to combine performance, economy and availability.

Based on the same coaxial design and technology as co-ax valves, cx-tec valves are available in a range of standard sizes, seal materials and configurations with the same features and benefits ... at lower costs!

And because they are standard products, they are available directly from stock.

co-ax valves inc. headquarter

ISO 9001:2008 Certificate

The Quality System of co-ax valves inc. including its implementation, meets the requirements of the standard ISO 9001:2008.

Contact

  • co-ax valves valves inc.
  • 1518 Grundy’s Lane
  • Bristol
  • PA 19007, USA

Privacy Policy & Legal Notice

Privacy Policy

co-ax valves inc. appreciates your interest in our products and your visit to our website www.cx-tec.us. At co-ax valves inc. we intend to give you maximum control about your personal information. Sometimes however we might need information from your part. Any personal information you will give us including your email address is used in the following way.

If you give us personal information in order to receive the information in return from us - for instance brochures, catalogues - we collect and store that information. That information enables us to fulfill your information request. We do not sell any of the information collected or stored about you.

The web site may contain links to non-co-ax valves inc. web sites. co-ax valves inc. is not responsible for the privacy practices of such web sites.

Legal Notice

Copyright Notice

The contents of the web site are copyright © 2015 co-ax valves inc., 1518 Grundy’s Lane, Bristol, PA 19007, USA. All Rights Reserved. Information on the web site, including but not limited to, text, images and sound, may not be reproduced, transferred, distributed or storaged without prior written permission by co-ax valves inc. Modifications to the contents of the web site are expressly prohibited. Some parts of the web site contain images that are subject to the copyright rights of their providers.

Trademarks

Unless otherwise indicated, on the web site displayed marks, corporate logos and emblems, are subject to the trademark rights of co-ax valves inc..

No Warranties and Representations

Information on this website is provided "as is". In no event co-ax valves inc. will be liable to any party or any direct, indirect, special or other consequential damages for any use of this website, or on any other hyperlinked website, including, without limitation, any lost profits, business interruption, loss of programs or other data on your information handling system or otherwise, even if we are expressly advised of the possibility of such damages.

Legal Effect

This exemption from liability is part of the internet offer. If, because of a legal position change, certain passages of this text or single verbalization lose there validity, even partially, the remaining part of this document will be unaffected. This will apply accordingly, if certain passages of this text or single verbalizations become legally ineffective.

co-ax valves inc. makes no warranties and/or representations about any other web site which you may access through this one. Such are provided only as a convenience and does not mean that co-ax valves inc. endorses or accepts any responsibility for the contents or the use of such web site. In addition, it is up to you to take precautions and to ensure that whatever you select for your use is free of such items as viruses, worms, Trojan horses and other items of a destructive nature.

Programming

MW WEBART Margraf & Wöhrl GbR, Germany
www.mw-webart.com